    Genset Controller DC60D/DC62D Series
    This series controller is specialized for Diesel / Gasoline / Gas Genset Start, Stop,Parameters monitoring, faults-checking as well as data setting.
    4.3 inch colorful LCD screen display with brand new UI design is adapted in this controller that the relative failures can be displayed directly. All the parameters can be displayed by simulated indicators and words.Besides, LCD screen can display various faults in the same time that the genset will be stopped once it can not work smoothly.
    There are Chinese/English interface options, more language can be set according to user’s request. All the parameters can be configured through the front face buttons or use programmable interface by RS485 or USB to adjust via PC.It can be widely applied for all kinds of auto control system of gensets.
    Main Features:
    32 units Micro-procession technology is used.
    4.3 inch TFT colorful big screen LCD, option language interface(Chinese/English), user’s language set if necessary.
    Indicator and number display through UI surface.
    Acrylic material is adapted to protect the screen.
    Silicone panels;
    USB Port: parameters can be set even without power through USD port to monitor in real time.
    Various kinds of parameters display.
    Input/output function, status can be shown directly.
    More categories of surface setting.
    Real time clock inside: preset time operate and auto maintenance is available. Genset working plan can be set as per week or month.
    Three class protection countdown function, which can set the maintenance time or date.
    Records function: relative faults shall be recorded in real time.
    Totally 6 relay’s output, among which 4 relay output can be self-configurable, each relay can be set as max 25 functions, besides, there are 4 groups as non-contact terminals.
    5 switch value input, and each can be set as max 30 functions.
    3 sensor simulation input connectors, 6 input types is configurable and various kinds of units can be set.
    Battery charging control function,which can protect the battery according to battery voltage status.
    Sensor can be self-defined by front face button or PC software.
    Adapt to 3P4W,1P2W,2P3W(120V/240V,50/60HZ)
    Various of crank conditions(RPM,Frequency, Oil Pressure) can be chosen
    Control Protection:Auto Start/Stop of genset,load transfer (ATS control) and perfect failure display and protection.
    Standard water-proof rubber gasket. The waterproof can reach IP54
    Module design: All the connections are adapted with European connectors so that installation, connection, repair and replacement can be more easily.
    Parameters Display:
    Engine RPM
    Engine oil pressure
    Engine water temperature
    Engine fuel temperature
    Engine cylinder temperature
    Engine Tank temperature
    Engine fuel level
    Engine battery voltage
    Charging voltage
    Mains Frequency (only for DC62D)
    Mains phase voltage L-N(only for DC62D)
    Mains phase voltage L-L(only for DC62D)
    Generator 3 Phase voltage L-N
    Generator 3 Phase voltage L-L
    Generator 3 phase current A
    Generator Frequency Hz
    Generator Power Factor COSφ
    Generator active power KW
    Generator apparent power KVA
    Generator reactive power KVar
    Current loading rate %
    Total average loading rate %
    Current consumption KWH
    Total consumption Kwh
    Total Crank times
    Current running time
    Total running time
    Three classes maintenance notice
    Protection:
    Over speed
    Under speed
    Low oil pressure
    High water temperature
    High Oil temperature
    High Cylinder Temperature
    High Tank temperature
    Low fuel level
    Low oil level
    External emergency alarm
    D+ Opened
    RPM Lost
    Sensor Open
    Over Frequency
    Under Frequency
    Over voltage
    under voltage
    over current
    Non-balance of current
    Over power
    Lack of Phase
    reverse phase sequence
    Gen load failure
    Gen unload failure
    Mains Load failure
    Mains unload failure
    Primary maintenance expire
    Secondary maintenance expire
    Maintenance expire
    Low water level alarm
    Emergency Stop
    Crank failure
    Over battery voltage
    Under Battery voltage
    Charging failure
    Battery Charging failure
    Stop Failure
    Parameters:
    Options
    Parameters
    Working voltage
    DC8V----36V Continuous
    Power consumption
    Standby:24V:MAX 1W
    Working:24V:MAX 5W
    AC Voltage Input
    1P2W 30VAC-276VAC(ph-N)
    2P3W 30VAC-276VAC(ph-N)
    3P4W 30VAC-276VAC(ph-N)
    Rotate speed sensor Frequency
    200-10000Hz
    MAX Accumulating Time
    99999.9Hours(Min Store time:6min)
    Fuel Relay Output
    16Amp DC+VE Supply voltage
    Start Relay Output
    16Amp DC+VE Supply voltage
    Programmable Relay output 1
    5Amp DC+VE Supply voltage
    Programmable Relay output 2
    5AMP Non-contact-Normal open--Normal close output
    Programmable Relay output 3
    5AMP Non-contact Normal Open output
    Programmable Relay output 4
    5AMP Non-contact normal open output
    Excitation output
    Max 1AMP DC+VE supply voltage
    Switch value input
    Available if connecting with Battery -
    Working condition
    -20-65℃
    Storage condition
    -40-85℃
    Protection Level
    IP54:when waterproof rubber gasket is added between controller and its panel
    Overall dimension
    210mm*160mm*50mm
    Panel cutout
    186mm*142mm
    Weight
    0.9Kg